Our company is a high-tech enterprise specializing in the research and development, production, and sales of transformers and switchgears. It originated from the Haian Transformer Factory established in 1978. As one of the pioneers in the transformer manufacturing industry in China, we have accumulated extensive industry experience and technical expertise, and we have been honored with the title of one of the first "China Famous-Brand Products" in the transformer industry.

 
  • 110kV Oil-immersed Transformer
    The 110kV oil-immersed transformer is a widely used power equipment, suitable for medium and high voltage transmission requirements. It performs exceptionally well in environments with significant...
    read more
  • Single-phase Pole-mounted Transformer
    Single-phase transformers are widely used as distribution transformers in Western developed countries, Southeast Asia, and North and South America. In power supply networks with scattered...
    read more
  • 220kV Oil-immersed Transformer
    A 220kV transformer is a high-voltage power equipment mainly used in the process of power transmission and distribution to increase or decrease voltage. It is typically composed of a core,...
    read more
  • 35kV Series Oil-immersed Distribution
    The three-phase oil-immersed distribution transformer produced by our company features a new type of insulation structure in the core, which enhances its short-circuit resistance. The core is made...
    read more
  • 20kVSeries Oil-immersed Distribution Transformer
    The 20kV series oil-immersed distribution transformers are crucial equipment in distribution networks and power supply systems of industrial and mining enterprises. They are widely used in...
    read more
  • 10kV Series Oil-immersed Distribution Transformer
    The 10kV series oil-immersed distribution transformer is a three-phase oil-immersed distribution transformer produced by our company. The core of the transformer adopts a new type of insulation...
    read more
 
Why choose us?

Global competitive pricing

Breaking the bias that "high quality must come at a high price," we make cutting-edge electromechanical equipment accessible. Leveraging 39 years of local supply chain expertise and a global logistics network, we reduce overall costs by over 30%. Our tiered pricing model ensures economies of scale—orders as small as 100 units enjoy a 10% price drop per unit. Transparent cost breakdowns detail raw materials, process premiums, and certification fees, eliminating hidden markups.

Zero-risk manufacturing

End-to-end risk control from blueprint to delivery ensures your success. First-article inspection locks in standards, guaranteeing consistency before mass production. Payment is phased for security: 30% deposit to start → 70% upon shipment → 100% after acceptance. Double warranty coverage: 24-month extended protection, surpassing the industry's standard 12 months.

 

Elite engineering & rapid customization

Our veteran R&D team brings 30+ years of power-electrical design expertise, backed by 50+ patents and technical collaboration with Shanghai Electric Power Research Institute (top-tier in China). Custom electromagnetic solutions delivered within 72 hours of request.

Reliable product quality

Every unit undergoes 100% testing under our comprehensive quality management system. Specialized products endure 72-hour salt spray tests, shock/vibration resistance, stable operation from -40°C to 55°C, and 95% RH humidity tolerance. Proven reliability: 10-year zero-failure record on South China Sea oil rigs.

 

Benefits of Oil-immersed Transformer
 

Cost-effective

They allow for cheap installation and maintenance and the need for change is minimal since the transformer is robust.

 

Reliable and durable

The transformers can sustain a variety of environmental conditions with low rates of failure which makes them dependable for long periods.

productcate-650-450

 

High efficiency

Less energy losses, enable oil immersed transformers to perform excellently under heavy loads.

 

Efficient cooling

Oil absorbs dissolves and radiates heat efficiently to avoid overheating of the transformer as well as consistent transformer operation at high loads.

 

Enhanced insulation and safety

The oil acts as an insulating cover for the windings reducing the risk of electrical discharges and increasing the life span of the transformer.

 

Versatile applications

Integrated factory strength to support all kinds of tape customization,with paper base,cloth base,glue,coating all raw material production capacity

 

Product Parameters

 

Energy Efficiency Grade Of 110 Kv Oil-immersed Three-phase Three-winding Off-load Tap-changer Transformer

Rated Capacity

Level 1

Level 2

Level 3

Short Circuit Impedance %

No-load loss

(kW)

Load loss

(75℃) (kW)

No-load loss

(kW)

Load loss

(75℃) (kW)

No-load loss

(kW)

Load loss

(75℃) (kW)

Step Up

Reduction Voltage

6,300

4.9

40

5.8

40

7.1

42

High School Grade 1 (High) 17.5 - 18.5 High School Grade 1 (Low) 10.5 Primary School Grade 1 (Low) 6.5

High School Grade 1 (Upper) 10.5 High School Grade 1 (Lower) 17.5 - 18.5 Middle School Grade 1 (Lower) 6.5

8,000

5.8

48

6.9

48

8.5

50

10,000

6.9

56

8.2

56

10.1

59

12,500

8.1

67

9.6

67

11.8

70

16,000

9.8

81

11.6

81

14.3

86

20,000

11.6

95

13.7

95

16.9

101

25,000

13.5

113

16

113

19.7

120

31,500

16.2

134

19.1

134

23.5

142

High School Grade 1 (High) 17.5 - 18.5 High School Grade 1 (Low) 10.5 Primary School Grade 1 (Low) 6.5

High School Grade 1 (Upper) 10.5 High School Grade 1 (Lower) 17.5 - 18.5 Middle School Grade 1 (Lower) 6.5

40,000

19.1

161

22.6

161

27.8

170

50,000

22.9

192

27

192

33.3

202

63,000

27.1

230

32

230

39.4

243

 

 
 

Precautions for Using Oil-immersed Transformer

To maximize performance while avoiding damage, follow these basic loading practices:

 

Analyze load profile

Ensure the load never exceeds the transformer’s rated capacity to prevent overheating or premature wear.

Consider environmental factors

Adjust operating parameters for ambient temperature and altitude to maintain optimal performance.

 

Schedule routine maintenance

Conduct regular checks, including oil testing and part replacements, for long-term efficiency and reliability.

Regularly monitor oil levels

Maintain consistent levels to preserve cooling and insulating performance. Overfilled tanks risk pressure buildup, while underfilled tanks reduce efficiency.

Use load tap changers

Tap changers help adjust voltage output to meet varying load demands, ensuring stability and efficiency.

 

 

How to Cooperate With Us

 

Contact us

The first and most important step is that you contact us. Our process begins the minute you call or email Pacific Transformer.

01

RFQ

Whether you request a quote for a new product design or an existing part, you should have a price in 48 hours.

02

Prototype

After you receive your pricing the prototyping process begins. This generally takes two weeks or less.

03

Production

Once we receive approval of the prototypes, the production turnaround time should be two weeks.

04

Manufacturing

Our ISO 9000 certified process is central to all manufacturing operations. All our products are made using our UL listed insulation system.

05

 

 

Packaging and Shipping

 

 

productcate-1000-826

 

 

FAQ

 

Q: Can oil-immersed transformers be installed indoors?

A: Yes, oil-immersed transformers can be installed indoors, but doing so requires significant safety measures to mitigate fire risks. Regulations typically mandate they be placed in fireproof vaults or rooms equipped with proper ventilation and oil containment systems, such as retention bunds, to prevent the spread of a fire or oil spill.

Q: What is a conservator tank in a transformer?

A: A conservator tank is an auxiliary reservoir mounted above the main tank in many oil-immersed transformers. Its purpose is to hold extra insulating oil, providing space for the oil to expand and contract with temperature changes during operation. This setup prevents oil overflow or pressure buildup and ensures the windings remain fully submerged in oil.

Q: Why is regular maintenance crucial for oil-immersed transformers?

A: Regular maintenance is crucial for oil-immersed transformers because the insulating oil's properties degrade over time due to heat, moisture, and oxidation. Routine oil testing, including Dissolved Gas Analysis (DGA), helps detect early signs of internal faults, moisture contamination, or overheating, which if left untreated, can lead to catastrophic failure.

Q: How does an oil-immersed transformer compare to a dry-type transformer?

A: Oil-immersed and dry-type transformers differ primarily in their cooling and insulation methods. Oil-immersed units use flammable oil, making them unsuitable for some indoor settings, while dry-type units rely on air or solid resin, which is safer indoors. Dry-type transformers have higher upfront costs but lower maintenance, whereas oil-immersed transformers have lower initial costs but require regular oil testing and treatment.

Q: Can vegetable oil be used as a transformer fluid?

A: Yes, vegetable oil-based transformer fluids, also known as natural esters, are increasingly used as an alternative to mineral oil. They offer superior biodegradability and a much higher flash point, significantly reducing fire risk and environmental impact. While some properties like pour point may differ, advancements have made them a viable and safer alternative.

As one of the leading oil-immersed transformer enterprises in China, we warmly welcome you to buy high quality oil-immersed transformer for sale here from our factory. Good service and reasonable price are available.

10kV Series Oil immersed Distribution Transformer, 110kV Oil immersed Power Transformer, 220kV Oil immersed Transformer