The 35KV photovoltaic box-type transformer is a product developed by our company in combination with advanced domestic and international technologies and experiences. It serves as a backup power source using solar photovoltaic conversion technology. The electricity generated by the photovoltaic generator at 690V is transformed into 35KV or 10KV through a step-up transformer and then fed into the system grid or user, thus completing the photovoltaic power generation task. Inside the box, there is an automatic switching device for dual power sources (solar and grid), a transformer, circuit breakers, and power supplies. The solar cells are respectively connected to the input terminals of the solar panels and the DC/AC inverter group, and the output terminals of the DC/AC inverter are connected to the input terminals of the dual power source automatic switching device. The dual power source automatic switching device is connected to the grid power supply through circuit breakers and transformers. It is an outdoor device integrating the 10KV distribution system and secondary system. This achieves the integration of the primary and secondary systems of the box-type substation, modular assembly, factory-based construction process, and simplified installation.
This product is applicable to various photovoltaic power generation sites and is the best matching product for photovoltaic power generation systems. It complies with standards such as GB/T17467 "High and Low Voltage Pre-assembled Substations" and DL/T537 "Technical Conditions for Ordering 6-5KV Box-type Substations".
Functional Features
● High reliability and high technological content. Main high and low voltage components are recommended to be imported products, with 20 years of maintenance-free operation.
● Modular and standardized assembly of functional modules, making it a powerful distribution product. All functions are relatively independent, allowing users to freely select various functional modules. High level of automation. On the 10KV side, CT, PT, protection, and communication devices can be installed. On the low-voltage side, a low-voltage protection and metering concentrator can be installed, enabling "three-remote" control of high and low-voltage switches and transformers.
● The enclosure adopts a double-layer, sealed, zinc-sprayed anti-corrosion structure, ensuring no corrosion for 20 years. Dust-proof, moisture-proof, and anti-condensation. Compact structure, large capacity, and small volume.
Product Usage Environment
● Altitude: ≤ 1000 meters;
● Ambient temperature: Maximum temperature +40℃, minimum temperature -25℃; Humidity: Daily average relative humidity does not exceed 95%, monthly average relative humidity does not exceed 90%;
● Wind speed: Outdoor wind pressure does not exceed 700Pa (34m/s);
● Vibration resistance: Horizontal acceleration no more than 3m/s², horizontal acceleration 1.5m/s²; Installation environment: Surrounding air is not significantly polluted by corrosive, flammable gases, etc., and the installation location has no severe vibration. If the conditions exceed the above regulations, it can be negotiated with our company.
Product Structure Features
Compact and simple structure, occupying less space, and quick installation. Convenient high and low voltage operation. According to environmental requirements, multiple colors of the shell can be selected to make the box transformer harmonious with the surrounding environment; Fully sealed and fully insulated structure, no need for insulation distance, reliably ensuring personal safety. Cable entry and exit are adopted, eliminating the need for a distribution room. This greatly reduces manufacturing and operating costs.
|
Technical SpecificationTechnical Specification |
|||
|
Name |
Item |
Unit |
Data |
|
High voltage unit |
Rat ed voltage |
kV |
40.5 |
|
Rat ed current |
A |
315 |
|
|
Withstan d current at rated |
kA/s |
20/2S |
|
|
Rated peak withstand current |
KA |
50 |
|
|
Mechanical life |
times |
>3000 times |
|
|
Low voltage unit |
Rated ultimate short-circuit breaking capacity |
kA |
65 |
|
Rat ed operating short-circuit breaking capacity |
kA |
50 |
|
|
Rat ed short-time withstand current |
kA/1S |
50 |
|
|
Transformer room unit |
Rat ed Capacity |
kVA |
800~2500 |
|
Impedance voltage |
% |
6.50% |
|
|
Tap range |
% |
(36.75±2x2.5%)0.69KV |
|
|
Connection group |
|
D.yn11 |
|
|
Cabinet unit |
Enclo sure rating |
|
IP3X |
|
Maxi mum temperature |
℃ |
40 |
|
|
Lowesttemperature |
℃ |
-40 |
|
|
Altitude |
m/s |
2500 |
|
|
Maxi mum wind speed |
m/s |
20.7 |
|
|
Seis mic intensity |
℃ |
8 |
|
|
Appearance size |
mm |
2700x2600x2000 |
|
Hot Tags: photovoltaic transformer, China photovoltaic transformer, Photovoltaic Step Up Transformer, Pre assembled Substation, PV Transformer, Wind driven Generator Transformer, Wind Turbine Step Up Transformer, Wind Turbine Transformer